Research speed reading in 2021. Healthcare careers for chemists are once again largely based in laboratories, although increasingly there is opportunity to work at the point of care, helping with patient investigation. , COA of Formula: https://www.ambeed.com/products/56-17-7.html, 56-17-7, Name is 2,2′-Disulfanediyldiethanamine dihydrochloride, molecular formula is C4H14Cl2N2S2, belongs to thiazines compound. In a document, author is Ali, Marwa F. B., introduce the new discover.
Development of HPLC method for estimation of glyoxylic acid after pre-column fluorescence derivatization approach based on thiazine derivative formation: A new application in healthy and cardiovascular patients’ sera
Glyoxylic acid (GA) is the intermediate metabolite in various mammalian metabolic pathways. GA showed high reactivity towards formation of advanced glycation end-products (AGEs); the main cause of pathogenesis and complications of many diseases. The presented study aimed to detect GA in healthy and cardiovascular patients’ (CV) sera; however analysis of GA in biological fluid is a challenge and requires chemical derivatization. Hence, a new, highly sensitive, time saving and reproducible pre-column fluorescence derivatization procedure coupled with high performance liquid chromatography (HPLC) method was developed. The derivatization method was based on reaction of 2-aminobenzenthiol (2-ABT), a fluorogenic reagent, with GA in acidic medium to form highly fluorescent thiazine derivative (290 and 390 nm for excitation and emission wavelengths respectively). The fluorescent derivative was separated within 6 min on a reversed-phase ODS column using an isocratic elution with a mixture of methanol-water (70:30, v/v%). The proposed method parameters were optimized and the method was validated. A good linearity in the concentration range (0.05-5.0 mu M) was obtained with detection limit (LOD) of 10 nM (200 fmol/injection), which is more sensitive than several previous methods. Moreover, the recovery results were within the range of 85.0-95.5 % and the intra- and inter-day precision results were <= 3.5%. It should be emphasized that this method is the first one for monitoring of GA in CV patients; to investigate its role for diagnosis and monitoring the severity and complications of this disease in clinical laboratory. If you’re interested in learning more about 56-17-7. The above is the message from the blog manager. COA of Formula: https://www.ambeed.com/products/56-17-7.html.
Reference:
Thiazine – an overview | ScienceDirect Topics,
,Thiazine | C4H5NS – PubChem